8kw 10kw 12kw IMHGC series Low frequency solar inverter with mppt

IMHGC series

Power frequency inverter control integrated machine, built-in MPPT controller, 3 times the maximum peak power, optional single-phase 120V or 220V output, can choose split-phase 120V and 220V output. Ideal for home use on two circuits for power tools, computers, audio/video components, and other sensitive electronic equipment. This inverter has a hard shell and is not limited to home, commercial, industrial, marine and other scenarios.

  1. Sine wave output
  2. Split-phase output 120V/240V (optional)
  3. real power output
  4. Built-in MPPT control, maximum photovoltaic input 450V
  5. Built-in AC charger, the maximum charging current can reach 60A
  6. Support external WIFI module
  7. 2 years warranty
Low frequency solar inverter

Low frequency solar inverter Detail

MODEL8kw10KW12KW
Continuous Output Power (W)8000W10000W12000W
Rated input voltage48VDC
Mains mode specifications:
Input voltage waveformSine wave (mains or generator)
Rated input voltage100V/110V/120V/220V/230V/240Vac
Low voltage    shutdown point92/184Vac±4%
Low pressure    recovery point97/194Vac ±4%
High voltage   shutdown point127/253Vac±4%
High pressure   recovery point121/243Vac±4%
Maximum AC input voltage135/270V rms
Rated input frequency50Hz/ 60Hz  (automatic detection)
Low voltage recovery point frequency40.5+0.3Hz ;
Low voltage cut-off  point frequency40+0.3Hz;
High voltage recovery point frequency69.5+0.3Hz;
High voltage cut-off  point frequency70+0.3Hz ;
Output voltage waveformConsistent with the input voltage waveform
Overload protectionCircuit breaker start
Short circuit protectionCircuit breaker start
Power Efficiency>95%
Conversion current30A
Conversion time      (Ac to Dc)10ms
Bypass switching currentYes
Bypass maximum    load current30A
Output voltage waveformSine wave
Power factor0~1.0
Rated output voltage (V)120/230Vac
Rated output   frequency (Hz)60/50Hz ± 0.3Hz
Automatic tracking  main frequency (Hz)Yes (from the first connection)
Output voltage range±2% rms
efficient>80%
Overload protection (SMPS load)(110%<load<125%) ±10%: disconnect the output voltage after 15 minutes
(125%<load <150%) ±10%: disconnect the output voltage after 10 seconds
Load >150% ±10%: Disconnect the output voltage after 20 seconds
Peak capacity(10s)24000VA30000VA36000VA
start the motor8HP10HP12HP
Short circuit protectionCurrent limit (power off after 10s)
Circuit breaker size63A
Rated DC input voltage48VDC
Power savingload ≦2W
Inverter dimensions(Length*width*height)698*415*200mm
Packing size (length*width*height)850*520*310mm
Inverter weight60+366+370+3
Packing operating weight62+368+372+3
Standard warranty2 year

What can the IMHGC series products do for you

Sistema de almacenamiento de energía

Suministro de Energía de Emergencia: El mecanismo de recorte de picos y llenado de valles puede descargar la energía almacenada durante las horas de bajo consumo, proporcionando energía de respaldo de emergencia para hacer frente a eventos inesperados y garantizar la operación segura y estable de la red eléctrica.

Mejora del Aprovechamiento de las Energías Renovables Variables: Los sistemas de almacenamiento de energía pueden captar energías renovables como la eólica y solar para cargar las baterías durante periodos de baja demanda de la red. Por el contrario, durante los picos de demanda, la energía química almacenada en las baterías se convierte nuevamente en energía eléctrica para su descarga. Este proceso mejora significativamente la tasa de utilización de las fuentes de energía renovable intermitentes, garantizando una integración más eficiente con la red eléctrica.

Conozca nuestros casos

energy blog
energy blog
energy blog